Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
J. appl. oral sci ; 30: e20210643, 2022. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1375708

ABSTRACT

Abstract Objective The aim of this study is to test, in vitro, the anti-cariogenic effect of experimental hybrid coatings, with nano clays of halloysite or bentonite, loaded with sodium fluoride or with a combination of sodium fluoride and stannous chloride, respectively. Methodology The varnish Fluor Protector (1,000 ppm of F-) was used as positive control and no treatment was the negative control. Enamel specimens (5 mm × 5 mm) were obtained from bovine teeth. The specimens (n=10) had their surfaces divided into two halves (5 mm × 2.5 mm each), in which one half received one of the treatments (Hybrid; Hybrid + NaF; Hybrid + NaF + SnCl2; Hybrid + NaF Loaded; Hybrid + NaF + SnCl2 Loaded). The specimens were submitted to a cariogenic challenge using a biofilm model (S. mutans UA159, for 5 days). Enamel surfaces both under and adjacent to the treated area were analyzed for mineral loss and lesion depth, by transverse microradiography. The pH of the medium was measured twice a day, and the fluoride release was analyzed. Additional specimens were submitted to confocal analysis. Results Data were statistically analyzed by two-way ANOVA followed by Tukey test (α=0.05). None of hybrid groups were able to reduce the lesion depth; the Hybrid + NaF group, however, was able to reduce mineral loss differing from the negative control (p=0.008). The groups showed no significant difference in the pH measurement and fluoride release. Confocal analysis confirmed that for all groups the biofilm growth was similar. Conclusion None of the hybrid groups reduced lesion depth, but the Hybrid + NaF group was able to promote protection against mineral loss.

2.
J. res. dent ; 9(2): 1-4, may-aug2021.
Article in English | LILACS-Express | LILACS | ID: biblio-1358581

ABSTRACT

Background. This cross-sectional study aimed to evaluate the impact of pain from dental urgencies on the oral health-related quality of life (OHRQoL). Methods. A sample of sixty-eight patients seeking urgent attention to a primary health unit were included. Clinical diagnosis and sociodemographic data were assessed, dental pain measured by visual analog scale (VAS) and numerical pain rating scale (NPRS). The Oral Health Impact Profile-14 (OHIP-14) instrument was used to measure the OHRQoL. Associations were analyzed using the Student t-test, except for types of urgencies, that were evaluated with one-way analysis of variance (ANOVA) test. Results. The most prevalent urgency type was of endodontic origin (81%). There was no difference between pain and other variables. The type of tooth showed significant differences in OHIP-14 scores. Conclusion. Dental urgencies were associated with a high level of pain and impacted negatively on the patients' OHRQoL. The type of tooth had a positive association the OHRQoL measures.

3.
ROBRAC ; 28(87): 232-239, out./dez. 2019. tab, ilus
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1096272

ABSTRACT

O objetivo deste trabalho foi avaliar o efeito do plasma atmosférico não-térmico (PANT), sozinho ou associado ao jateamento ou adesivo, e do tempo de armazenamento em água na resistência de união por cisalhamento (RUC) do reparo de cerâmicas CAD/CAM de matriz resinosa (CMR) com resina composta. Amostras de 14x7x1mm de três CMRs, Enamic (VITA Zahnfabrik), Cerasmart (GC Corp.) e Lava Ultimate (3M Oral Care), foram obtidas e submetidas ao envelhecimento artificial (EQ-UV, Equilam) por 300 horas. Os seguintes tratamentos de superfície foram realizados: (1- Controle) jateamento + silano + adesivo; (2) PANT; (3) PANT + adesivo; (4) jateamento + PANT. Cilindros de resina composta (Spectra Smart, Dentsply Sirona, 1,5 mm diâmetro e altura) foram aderidos às superfícies tratadas e a RUC foi avaliada em uma máquina de ensaio universal (EZ Test, Shimadzu) após 24 horas ou 1 ano de imersão em água, a 37oC (n=10). No geral, o tratamento controle obteve os melhores resultados de RUC, comparado aos grupos tratados com PANT. Houve redução da RUC após 1 ano de imersão em água para a maioria dos grupos, entre eles para o controle do Enamic e Lava Ultimate, enquanto Cerasmart não mostrou redução. O tratamento com PANT, sozinho ou associado a outro tratamento, não foi capaz de aumentar a RUC do reparo das CMRs com resina composta. O tratamento controle parece ser o melhor método de reparo das CMRs, principalmente considerando-se a longevidade do tratamento.


The objective of this study was to evaluate the effect of nonthermal atmospheric plasma (NTAP), alone or combined with sandblasting or adhesive, and water-storage time on the shear bond strength (SBS) of resin composite repair of resin matrix ceramics (RMC). Samples (14x7x1mm) of three RMCs, Enamic (VITA Zahnfabrik), Cerasmart (GC Corp.), and Lava Ultimate (3M Oral Care), were prepared and submitted to artificial aging (EQ-UV, Equilam) for 300 h. The following surface treatments were performed: (1- Control) sandblasting + silane + adhesive; (2) NTAP; (3) NTAP + adhesive; (4) sandblasting + NTAP. Resin composite cylinders (Spectra Smart, Dentsply Sirona, 1,5 mm diameter and height) were bonded to the treated surfaces and the SBS was evaluated in a universal testing machine (EZ Test, Shimadzu) after 24 h or 1 year of water storage, at 37oC (n=10). In general, the control treatment obtained the best SBS results, compared to groups treated with NTAP. There was a decrease in SBS after 1 year of water immersion for most groups, including the control treatment for Enamic and Lava Ultimate, while Cerasmart presented no reduction. The treatment with NTAP alone or combined with another treatment, was not capable of increasing the SBS of resin composite repair to RMCs. Control treatment seems to be the best method for repairing CMRs, mainly considering the treatment longevity.

4.
Hig. aliment ; 33(288/289): 1782-1785, abr.-maio 2019.
Article in Portuguese | LILACS, VETINDEX | ID: biblio-1482404

ABSTRACT

O Brasil no primeiro semestre de 2016 exportou 571,5 mil toneladas de produtos cárneos. O Centro-Oeste tem papel importante nessa expansão, sendo a criação pecuária na região favorecida pela proximidade de centros produtores de grãos e à pouca distância de abatedouros-frigoríficos. As questões sanitárias são de grande importância no âmbito comercial para produtos de origem animal, e é crescente a preocupação de que estas devam se tornar barreiras para alguns criadores que não conseguem atingir qualidade nos seus produtos. Dessa forma, analisou-se 788.885 bovinos abatidos e contabilizou-se as condenações por abscessos e contaminações. Os resultados apontam 0,717% no ano de 2015, 1,051% em 2016 e 2,016% em 2017 de condenações por contaminações e 0,089% no ano de 2015, 0,081% em 2016 e 0,068% em 2017, por abscessos. Através dos achados pode-se concluir que contaminações e abscessos são causas frequentes de condenações, acarretam em prejuízo financeiro e alteram a qualidade da carne.


Subject(s)
Animals , Cattle , Animal Culling/statistics & numerical data , Abscess/veterinary , Meat , Food Contamination/statistics & numerical data , 24454 , Abattoirs
5.
Hig. aliment ; 33(288/289): 1948-1951, abr.-maio 2019.
Article in Portuguese | LILACS, VETINDEX | ID: biblio-1482438

ABSTRACT

Atualmente os consumidores buscam cada vez mais alimentos seguros, de qualidade e produzidos de forma sustentável, dessa forma os produtores e empresas tentam ao máximo atender essas buscas, melhorando o manejo da propriedade ao frigorifico, trazendo cada vez mais o ideal de bem-estar animal. O bem-estar animal tem como objetivo evitar o sofrimento desnecessário dos animais nas etapas que antecedem o abate, ainda que com sua implementação, ainda há muitas perdas econômica e qualitativa das carcaças devido à presença de contusões. As contusões podem ocorrer pelas mais diversas causas, de manejo inadequado até rodovias precárias. Diante do exposto, considerando a importância das contusões para a qualidade das carcaças, o presente trabalho foi realizado em um abatedouro-frigorífico de bovinos sob Serviço de Inspeção Federal localizado em Mato Grosso, e teve como objetivo quantificar as carcaças com contusões, além de apontar o tipo de contusão e a região anatômica acometida. De um total de 4579 animais avaliados, 2829 (61,78%) apresentaram algum tipo de contusão, desde as pequenas e superficiais até as maiores e profundas. Em relação ao grau das contusões, a que teve maior ocorrência foi a de grau I (59,31%), seguida pelo grau II (37,39%) e grau III (3,28%). Quanto à localização anatômica, houve um predomínio de contusões na região do traseiro, seguido pelo gradil costal (PA), lombo e dianteiro. Portanto, observamos a necessidade da atualização dos conceitos de bem-estar dentro de toda a cadeia produtiva, além de treinamento de funcionários em relação ao manejo pré-abate, visando não comprometer o animal e a qualidade da carne.


Subject(s)
Animals , Cattle , Animal Culling , Animal Welfare , Meat/analysis , Contusions/veterinary , Food Contamination , Abattoirs
6.
RPG rev. pos-grad ; 9(2): 142-148, abr.-jun. 2002. tab
Article in Portuguese | LILACS, BBO | ID: lil-336390

ABSTRACT

A condiçäo mínima para que produtos comerciais tenham potencial anticárie é a presença de uma concentraçäo significativa de flúor solúvel nos mesmos. Considerando-se que essa condiçäo é inclusive regulamentada por lei, o presente trabalho teve por objetivo primário analisar as concentraçöes de íon flúor de sete marcas comerciais de enxaguatórios bucais. Para isso utilizou-se um eletrodo específico para flúor Orion 96-09 acoplado a um analisador de íons Orion EA 940, ambos previamente calibrados, sendo o objetivo secundário deste trabalho descrever operacionalmente a realizaçäo dessa análise. Os resultados encontrados (média ñ dp; n = 3) de íon flúor (ppm) foram: Kolynos Flúor© - 213,3 ñ 9,0; Fluordent© - 223,7 ñ 1,7; Plax Kids© - 229,1 ñ 3,8; Cepacol Júnior© - 218,6 ñ 1,1; Sorriso Herbal© - 220,6 ñ 6,5; Fresh Breath Menta© - 88,7 ñ 1,1; Fresh Breath Menta Azul© - 88,0 ñ 3,7. Os resultados mostraram que apenas os enxaguatórios da marca Fresh Breath estavam em desacordo com a Portaria nº 29 de 28 de agosto de 2000 da Agência Nacional de Vigilância Sanitária (Anvisa) do Ministério da Saúde do Brasil e que a técnica de análise com eletrodo íon-específico é precisa e exata


Subject(s)
Fluorine/analysis , Ion-Selective Electrodes , Mouthwashes
SELECTION OF CITATIONS
SEARCH DETAIL